The noise emission is up to the standard, in line with the standard III of GB12348 "Noise Standard for Industrial Enterprise Boundary";

The treatment of solid hazardous waste meets the requirements of laws and regulations;

Ensure that the company's products and purchase products harmful chemical substances (lead, cadmium, mercury, chromium six dielectric) 100% is not exceeded the standard;

Ensure that the company's products and purchased products do not contain conflict metals such as gold (Au), tantalum (Ta), tungsten (W) and tin (Sn) produced by minerals in conflict areas;

Domestic sewage management meets regulations;

The fire incidence rate is 0.

Conflict minerals refer to Metal minerals such as gold (Au), tantalum (Ta), tungsten (W), cobalt (Co), tin (Sn) and other metals produced from Congo and surrounding 10 countries (DR Congo, Ganga, Sudan, Rwanda, Burundi, Uganda, Zambia, Angola, Tanzania, Central African Republic), through smuggling trade channels, by non-governmental military groups or non-military factions in the controlled conflict area. ETEK prohibits use of metals from conflict mining areas;

Prohibit the procurement and use of conflict metal raw materials produced in mining areas in conflict areas;

Ensure that products do not use "conflict minerals" from conflict areas;

Communicate this requirement to its upstream suppliers.

Reliability Assurance
Strict standardized quality control
Relevant reliability assessment items and standards

Test Item Item Condition Sampling Size/Acc Frequency
Pre - Condition IR "Baking: 125°C,24hrs THT: Time and conditions per IPC/JEDEC J-STD-020 based on device MSL level Reflow: 260°C, 3times" 77*7/0 New Item
Reflow IR 260°C,3times 77/0 By lot
High Accelerated Stress Test HAST 130°C,85%R.H, 96/168hrs 77/0 By lot
Thermal Shock Test TST -65°C~150°C ,100/500Cycles,Dwell=15min 77/0 By lot
High Temperature StorageTest HTST 150°C,168/500/1000hrs. 22/0 Monthly
High Temperature Operating Life Test HTOL 125°C,VDD=AMR*90%,168/500/1000hrs 22/0 Monthly
Low Temperature Operating Life Test LTOL -40°C,VDD=AMR*90%,168/500/1000hrs 22/0 Monthly
Temperature Humidity Storage Test Aging 85°C.85%R.H.VDD=AMR*90%,168/500/1000hrs 22/0 Monthly
Pressure Cook Test PCT 121°C, 100%R.H.2 atms,96hrs 22/0 Monthly
CNAS Certified Reliability Laboratory